Showing results: 151 - 165 of 2630 items found.
-
LineTroll 110Eμ -
Nortroll
Linetroll 110E contains magnetic and electric field sensors surveying line current and line voltage. The magnetic sensor automatically adapts to line current, detecting preset current increases. The electric field sensor is monitoring the presence of line voltage. The sensor signals are processed and compared with user set alarm criterias.
-
B-1012-B -
ROSS ENGINEERING CORPORATION
High Voltage Probes for Very Low Current Power Supply Voltage Measurementto 120kV, such as Electrostatic Paint Spray Applications...
-
PA60Bi -
Ponovo Power Co., Ltd.
PA60Bi is the panel-mounted power amplifier, which can produce 3-phase current, with maximum RMS phase current of 60A and maximum output power of 800VA, and 4-phase voltage, with maximum RMS phase voltage of 120V and maximum output power of 60VA.
-
STMicroelectronics
A current sense amplifier is a differential amplifier providing an analog output voltage proportional to the current flowing into a load connected on its input.
-
Milwaukee Electric Tool Corporation
A clamp meter is an electrical tester that combines a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage.
-
Shenzhen Graigar Technology Co.,Ltd.
A clamp meter is an electrical tester that combines a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage.
-
FD1772B -
Lisun Electronics Inc.
• Constant DC output 0-6A• Auto or manual current sweep output• 5 current range output• Output voltage range: 0-11.5V• Current accuracy ± (1%reading + 2digit)
-
U60 -
LEMSYS
To measure leakage current ID, IR at given voltage range.
-
-
KM-PS-302DII / 303DII / 305DII -
Kusam Electrical Industries Limited
* High Stability* ON/OFF output switch* Fixed 5V Supply output*Coarse & fine adjustment setting for both Voltage & Current.* Full scale long duration time output.*3 digit display for each Voltage & Current function.
-
Shanghai MCP Corp
.Monophase and triphase Balance measures.Widerband power measure up to audio frequency .Small power measure.Connection and operation simplicity.Accuracy:better than 2% at the full current and voltage scale .Protection against over-currents by fuses .Over current and over voltage indictor
-
FuG Elektronik GmbH
Autoranging power supplies are power supplies with stepless range adjustment . Within a fixed power limit - up to max. 9,000W - the full output power is delivered over a wide voltage and current range. The working range is not only extended by higher voltage, but also by higher current. The output voltage is between 150V and 3000V.
-
MPS-H-1 Series -
Matrix Technology Inc.
MPS-H-1 series DC power supply is a new generation of high-quality linear DC power supply, with remote voltage compensation function, automatic conversion of voltage stabilization and current, high stability, high reliability, high precision, and display output voltage and current at the same time. Very high cost-effective advantage.
-
NI
The Power Measurements Conditioner provides voltage and current signal conditioning for a supported data acquisition module or device to make up to four simultaneous power measurements per conditioner. It also includes attenuation for voltage channels up to 2,000 V and has power, communication, and signal lines for current measurements from current transducers.
-
Handheld Turns Ratio & Winding Resistance Tester TWR-H -
Amperis sl
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.